Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Oral Health ; 24(1): 404, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38553668

RESUMEN

BACKGROUND: Up to date, interdental brushes (IDB) are the first choice for interdental cleaning because of their cleaning efficacy. Cylindrical ones must be selected individually according to the size/morphology of the interdental area (IDR), whereas conical ones cover a larger variability of IDR. However, there is a trend on the part of patients towards interdental rubber picks (IRP) which are in general conically shaped, and which seem to be linked with lower cleaning efficacy. A new IRP with an Archimedes´ screw design was developed to overcome this limitation. Therefore, the in vitro study aimed to measure the experimental cleaning efficacy (ECE) and force (ECF) during interdental use of IDBs versus the new IRP type. METHODS: Three IRPs with different tapers (PHB angled: 0.039, PHB straight S: 0.027, Vitis straight M: 0.045; all Flexipicks, Dentaid, Cerdanyola del Vallès, Spain) were compared to one IDB (Interprox micro PHD 0.9, Dentaid, Cerdanyola del Vallès, Spain). IDR were reproduced by a 3D-printer (Form2, Formlabs Sommerville, MA, USA) according to human teeth and matched to equivalent pairs (isosceles triangle, concave, convex) in three different diameters (1.0 mm,1.1 mm,1.3 mm). Covered with simulated biofilm, pre-/ post-brushing situations of IDR (standardized, computer-aided ten cycles) were photographed and quantified by digital image subtraction to calculate ECE [%]. ECF were registered with a load cell [N]. Statistically significant differences were detected using the Mann-Whitney-U-test and the Kruskal-Wallis-test with Bonferroni correction for multiple testing. RESULTS: Overall, the ECE (mean ± SD) was higher for IDB micro 0.9 (45.95 ± 11.34%, p < 0.001) compared to all IRPs (PHB angled: 25.37 ± 15.29%; PHB straight: 22.28 ± 16.75%; Vitis straight: 25.24 ± 12.21%; p ≤ 0.001), whereat best ECE was achieved in isosceles triangle IDR of 1.0-1.1 mm (IDB micro 0.9: 70.7 ± 7.7%; PHB angled S: 57.30 ± 4.43%; p < 0.001). The highest ECF occurred for Vitis straight M with 2.11 ± 0.46 N, while IDB micro 0.9 showed lowest ECF values (0.64 ± 0.14 N; p < 0.001). CONCLUSIONS: IRP with an Archimedes´ screw design and a higher taper were associated with advanced ECE but also higher ECF, nevertheless, ECE didn't reach the cleaning efficacy of conventional IDBs.


Asunto(s)
Dispositivos para el Autocuidado Bucal , Placa Dental , Humanos , Goma , Cepillado Dental/métodos , Tornillos Óseos
2.
BMC Oral Health ; 22(1): 459, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36320016

RESUMEN

BACKGROUND: The familiar aids for interdental cleaning such as dental floss or interdental brushes (IDB) are often associated with difficult handling or an increased potential for trauma. Interdental picks (IRP), which have no metal core and silicone flaps instead of nylon brushes, offer the alternative. However, in-vitro studies found a lower cleaning effectiveness combined with higher forces for cleaning compared with conventional IDBs. The aim of this in-vitro study was to measure the experimental cleaning forces (ECF) using IRP with versus without an artificial saliva (AS; GUM Hydral, Sunstar Suisse SA, Etoy, Switzerland). METHODS: The test set-up was developed to investigate the cleaning of 3D-printed interdental area (IDR) mimicking human teeth (Form 2, Formlabs Sommerville, MA, USA) under standardized conditions. Three different morphologies (isosceles triangle, convex, concave) and three different sizes (1.0 mm,1.1 mm,1.3 mm) were used. Two different IRPs (GUM Soft-picks Advanced: SPA versus GUM Soft-picks Advanced Plus: SPA+, Sunstar Suisse SA, Etoy, Switzerland) in three sizes (small, regular, large), were used with versus without AS. ECF during ten cleaning cycles were recorded by a load cell [N]. RESULTS: Using AS leaded to significant lower values for ECF than without (1.04 ± 0.66 N versus 1.97 ± 1.01 N, p < 0.001). In general, a lower ECF was recorded for convex IDR compared to isosceles triangle and concave morphologies (p < 0.001) as well as for gap sizes of 1.3 mm compared to the smaller sizes (p < 0.001). For SPA+ we found significantly higher force values than for SPA (1.67 ± 0.93 N versus 1.31 ± 0.97 N, p < 0.001) independent of the use of AS. CONCLUSION: Within the study´s in-vitro limitations, we found AS reduced ECF of IRPs by half and allowed using larger diameters interdentally, which could be associated with (1) a higher cleaning effectiveness and (2) a higher acceptance e.g. of patients with dry mouth. This has to be confirmed by further clinical investigations.


Asunto(s)
Dispositivos para el Autocuidado Bucal , Placa Dental , Humanos , Compuestos de Benzalconio , Goma , Saliva Artificial , Cepillado Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...